Click here to Skip to main content
16,008,183 members
Home / Discussions / COM
   

COM

 
Generalplease help me !! I get E_NOINTERFACE error... using CLSCTX_LOCAL_SERVER Pin
johnstapleton27-Mar-02 5:59
johnstapleton27-Mar-02 5:59 
GeneralServer name problem Pin
27-Mar-02 4:11
suss27-Mar-02 4:11 
GeneralUrgent!! Creating own stream in a Word Document Pin
26-Mar-02 23:02
suss26-Mar-02 23:02 
GeneralPointer to an ActiveX in VB Pin
Jerome Conus26-Mar-02 19:46
Jerome Conus26-Mar-02 19:46 
GeneralCOM Object Pin
Nick Parker26-Mar-02 18:16
protectorNick Parker26-Mar-02 18:16 
GeneralRe: COM Object Pin
Paul M Watt26-Mar-02 18:53
mentorPaul M Watt26-Mar-02 18:53 
GeneralRe: COM Object Pin
Michael Dunn26-Mar-02 19:31
sitebuilderMichael Dunn26-Mar-02 19:31 
GeneralReturning Safearray from remote DCOM Pin
David Spain25-Mar-02 12:34
David Spain25-Mar-02 12:34 
The program, in C++, is sending a call to a DCOM object installed on a remote NT machine, and am trying to return a Safearray of float (as SAFEARRAY **ppfloatarray), have set that parameter as [in,out], (plus other parameters before this as [in]). Client is running Windows 98. On the client end, the data is not being written back to the passed-in safearray, and HRESULT returned is 8002000D, array is locked.

How is the client and server to be set up to do this? My solution was to try various combinations for the flags in the fFeatures member of the safearray, also to try setting the array to locked or unlocked before it was sent and before it was returned from server. I have a debug text file written, so I know that the DCOM object is executing, and the correct values are written to the safearray and are there just before it returns.


David Spain, C++ Applications Programmer
GeneralRe: Returning Safearray from remote DCOM Pin
Sayan Mukherjee26-Mar-02 2:36
Sayan Mukherjee26-Mar-02 2:36 
GeneralRe: Returning Safearray from remote DCOM Pin
David Spain26-Mar-02 3:56
David Spain26-Mar-02 3:56 
GeneralRe: Returning Safearray from remote DCOM Pin
David Spain27-Mar-02 2:55
David Spain27-Mar-02 2:55 
GeneralBuilding interface to IActiveScriptSite and IActiveScriptSiteWindow with MFC and ATL 7.0 Pin
25-Mar-02 7:50
suss25-Mar-02 7:50 
GeneralProblems with suspend/resume comm thread. Pin
dejan.n25-Mar-02 4:05
dejan.n25-Mar-02 4:05 
GeneralATL CLSCTX_LOCAL_SERVER get E_NOINTERFACE error... Pin
johnstapleton25-Mar-02 2:46
johnstapleton25-Mar-02 2:46 
GeneralRe: ATL CLSCTX_LOCAL_SERVER get E_NOINTERFACE error... Pin
jfugate18-Jul-02 5:03
jfugate18-Jul-02 5:03 
QuestionHow do I retrieve the container window Ptr(HWND) in the COM? (eg.IE client area) Pin
xelin25-Mar-02 1:28
xelin25-Mar-02 1:28 
AnswerRe: How do I retrieve the container window Ptr(HWND) in the COM? (eg.IE client area) Pin
Amit Dey30-Mar-02 0:33
Amit Dey30-Mar-02 0:33 
GeneralRe: How do I retrieve the container window Ptr(HWND) in the COM? (eg.IE client area) Pin
xelin3-Apr-02 0:21
xelin3-Apr-02 0:21 
QuestionHow to specify an ATL server location at runtime Pin
HawkSoftware22-Mar-02 19:52
HawkSoftware22-Mar-02 19:52 
AnswerRe: How to specify an ATL server location at runtime Pin
Not Active26-Mar-02 15:04
mentorNot Active26-Mar-02 15:04 
GeneralRe: How to specify an ATL server location at runtime Pin
HawkSoftware26-Mar-02 18:28
HawkSoftware26-Mar-02 18:28 
Generalefficiency question with in proc COM methods Pin
moredip22-Mar-02 12:16
moredip22-Mar-02 12:16 
GeneralRe: efficiency question with in proc COM methods Pin
Tim Smith22-Mar-02 13:18
Tim Smith22-Mar-02 13:18 
GeneralRe: efficiency question with in proc COM methods Pin
22-Mar-02 13:52
suss22-Mar-02 13:52 
Generaldialog boxes Pin
shingai22-Mar-02 9:41
shingai22-Mar-02 9:41 

General General    News News    Suggestion Suggestion    Question Question    Bug Bug    Answer Answer    Joke Joke    Praise Praise    Rant Rant    Admin Admin   

Use Ctrl+Left/Right to switch messages, Ctrl+Up/Down to switch threads, Ctrl+Shift+Left/Right to switch pages.