|
Well, if the control doesn't raise any useful events, your options are limited, and the timer solution is about all there is (Just make sure it's sleeping between checks, not calling continuously).
Maybe you could hide the complexity with private classes... I'm still in favor of the wrappers to merge all the different possibilities into a single event type... When you pass in the control, it'll check for a few common types (For a TextBox, it would look for TextChanged. For a checkbox, CheckedChanged. If it's an INotifyPropertyChanged, PropertyChanged). Depending on the type of control passed, it creates a different wrapper that hooks the necessary event and supplies a simple Changed event. If it can't find an event to hook, it falls back to the timer method...
public void MonitorObject(object obj, Delegate valueToMonitor)
{
if (obj is TextBox)
Add(new TextChangedWatcher(obj as TextBox, valueToMonitor));
else if ...
else
Add(new DefaultObjectWatcher(obj, valueToMonitor));
}
private class ObjectWatcher
{
public event EventHandler Changed;
private Delegate ResultCallback { get; set; }
private object PreviousValue { get; set; }
protected void OnCheckValue()
{
object newValue = ResultCallback.Invoke();
if (!object.Equals(PreviousValue, newValue))
{
PreviousValue = newValue;
if (Changed != null) Changed(this, EventArgs.Empty);
}
}
}
private class TextChangedWatcher : ObjectWatcher
{
public TextChangedWatcher(TextBox ctl)
{
}
}
private class CheckedChangedWatcher : ObjectWatcher
{
}
private class NotifyObjectWatcher : ObjectWatcher
{
}
private class DefaultObjectWatcher : ObjectWatcher
{
}
Anyway... The idea would be to hook events when possible, and only fall back to the timer when there are no known events to hook.
|
|
|
|
|
Yes, you are right Ian.
I guess I'll go for the wrapper (I like wrappers anyway).
Maybe I'll replace the timer-part at a later time, but for now it'll suit my needs
Thank you Ian for your input, I really appreciate that,
best regards
Andy
|
|
|
|
|
Why is dynamic polymorphism so called? Want to know why not how it is achieved !
|
|
|
|
|
|
Here[^] are some reasons.
Just say 'NO' to evaluated arguments for diadic functions! Ash
|
|
|
|
|
Oh!! Thats the bunch from which I selected one.
|
|
|
|
|
Most of the link gives how to achieve dynamic polymorphism. I dint get an accurate answer
|
|
|
|
|
There's a fairly reasonable definition of dynamic polymorphism here[^].
|
|
|
|
|
maB_J wrote: I dint get an accurate answer
What do you mean by accurate? Did you read the first link in the list I sent you? It gives a full definition of Dynamic Polymorphism; you could also go to Bjarne Stroustrup's web site and read everything he has to say about it.
Just say 'NO' to evaluated arguments for diadic functions! Ash
|
|
|
|
|
hey guys..i try to add datas by stored procedure with 15 parameters..it works well..the problem is in my ProcessLayer..i have Firmalar class like below.
public class Firmalar
{
public string firma_adi { get; set; }
public string yetkili1 { get; set; }
public string gsm1 { get; set; }
public string email1 { get; set; }
public string yetkili2 { get; set; }
public string gsm2 { get; set; }
public string email2 { get; set; }
public string yetkili3 { get; set; }
public string gsm3 { get; set; }
public string email3 { get; set; }
public string telefon1 { get; set; }
public string telefon2 { get; set; }
public string telefon3 { get; set; }
public string telefon4 { get; set; }
public string telefon5 { get; set; }
}
and i try to add data in my processLayer like that
public void InsertFirm(Firmalar fir)
{
try
{
fir = new Firmalar();
cmmd = d.InsertData();
cmmd.Parameters.AddWithValue("@firmanin_adi", System.Data.SqlDbType.NVarChar).Value = fir.firma_adi;
cmmd.Parameters.AddWithValue("@yetkili1", System.Data.SqlDbType.NVarChar).Value = fir.yetkili1;
cmmd.Parameters.AddWithValue("@gsm_num1", System.Data.SqlDbType.NVarChar).Value = fir.gsm1;
cmmd.Parameters.AddWithValue("@e_mail1", System.Data.SqlDbType.NVarChar).Value = fir.email1;
cmmd.Parameters.AddWithValue("@yetkili2", System.Data.SqlDbType.NVarChar).Value = fir.yetkili2;
cmmd.Parameters.AddWithValue("@gsm_num2", System.Data.SqlDbType.NVarChar).Value = fir.gsm2;
cmmd.Parameters.AddWithValue("@e_mail2", System.Data.SqlDbType.NVarChar).Value = fir.email2;
cmmd.Parameters.AddWithValue("@yetkili3", System.Data.SqlDbType.NVarChar).Value = fir.yetkili3;
cmmd.Parameters.AddWithValue("@gsm_num3", System.Data.SqlDbType.NVarChar).Value = fir.gsm3;
cmmd.Parameters.AddWithValue("@e_mail3", System.Data.SqlDbType.NVarChar).Value = fir.email3;
cmmd.Parameters.AddWithValue("@tlfn1", System.Data.SqlDbType.NVarChar).Value = fir.telefon1;
cmmd.Parameters.AddWithValue("@tlfn2", System.Data.SqlDbType.NVarChar).Value = fir.telefon2;
cmmd.Parameters.AddWithValue("@tlfn3", System.Data.SqlDbType.NVarChar).Value = fir.telefon3;
cmmd.Parameters.AddWithValue("@tlfn4", System.Data.SqlDbType.NVarChar).Value = fir.telefon4;
cmmd.Parameters.AddWithValue("@tlfn5", System.Data.SqlDbType.NVarChar).Value = fir.telefon5;
cmmd.ExecuteNonQuery();
}
and inside of my form's code i try to send parameters...
private void btnEkle_Click(object sender, EventArgs e)
{
try
{
if (txtFirma_adi.Text.Length != 0)
{
firma = new Firmalar();
h.InsertFirm(firma);
firma.firma_adi = txtFirma_adi.Text;
firma.yetkili1 = txtYetkili_adi.Text;
firma.gsm1 = txtGsm.Text;
firma.email1 = txtEmail.Text;
firma.yetkili2 = txtYetkili2.Text;
firma.gsm2 = txtGsm2.Text;
firma.email2 = txtEmail2.Text;
firma.yetkili3 = txtTetkili3.Text;
firma.email3 = txtEmail3.Text;
firma.gsm3 = txtGsm3.Text;
firma.telefon1 = msktlf1.Text;
firma.telefon2 = mskTlf2.Text;
firma.telefon3 = mskTlf3.Text;
firma.telefon4 = msktlf4.Text;
firma.telefon5 = mskTlf5.Text;
}
}
}
but the values dont go to my stored procedure..and it gives error sp_AddDatas expects parameter @firmanin_adi...so how i can send the values to my stored procedure..
vemedya.com
|
|
|
|
|
erdinc27 wrote: fir = new Firmalar();
Inside method InsertFirm(Firmalar fir) why are you again intializing Object? Use the received object itself.
|
|
|
|
|
hey Hiren..thanks for the reply..i changed as u said and now it adds first parameter but not second parameter??
so why it happens ?
vemedya.com
|
|
|
|
|
erdinc27 wrote: cmmd.Parameters.AddWithValue("@yetkili1", System.Data.SqlDbType.NVarChar).Value = fir.yetkili1;
You have used blockquoted way to add parameter with value.
But AddWithValue having format of AddWithValue(string Parametername,object value)
Your statement must generate compile time error I think,
Use Like
cmmd.Parameters.AddWithValue("@yetkili1",fir.yetkili1);
|
|
|
|
|
i tried as u suggested but still nothing..it gives the same error..what else can be reason for that error ?
vemedya.com
|
|
|
|
|
Okey As you have done all suggested things.
Now Add one thing and see the magic.
After intializing command object which is cmmd, Put a line like.
cmmd.CommandType = CommandType.StoredProcedure
|
|
|
|
|
again me..i added the code u said but still no magic
u have any other suggesstion ?
vemedya.com
|
|
|
|
|
I think now you might have some problem with InsertData() Method. Can you show us that method,So that we can have better Idea of a whole scenario.
|
|
|
|
|
here is my InsertData()method
public SqlCommand InsertData()
{
cmd = new SqlCommand("sp_AddDatas", con);
cmd.CommandType = CommandType.StoredProcedure;
return cmd;
}
and here is the sp_AddDatas
ALTER procedure [dbo].[sp_AddDatas]
(
@firmanin_adi nvarchar(70),
@yetkili1 nvarchar(30),
@gsm_num1 nvarchar(20),
@e_mail1 nvarchar(30),
@yetkili2 nvarchar(30),
@gsm_num2 nvarchar(20),
@e_mail2 nvarchar(30),
@yetkili3 nvarchar(30),
@gsm_num3 nvarchar(20),
@e_mail3 nvarchar(30),
@tlfn1 nvarchar(20),
@tlfn2 nvarchar(20),
@tlfn3 nvarchar(20),
@tlfn4 nvarchar(20),
@tlfn5 nvarchar(20)
)
as
BEGIN
Insert Into Firmalar(firma_adi,yetkili_ad1,Gsm1,email1,yetkili_ad2,Gsm2,Email2,yetkili_ad3,Gsm3,Email3,Telefon1,Telefon2,Telefon3,Telefon4,Telefon5)Values (@firmanin_adi, @yetkili1,@gsm_num1,@e_mail1,@yetkili2,@gsm_num2,@e_mail2, @yetkili3,@gsm_num3,@e_mail3,@tlfn1,@tlfn2,@tlfn3,@tlfn4,@tlfn5)
END
vemedya.com
|
|
|
|
|
Now I don't have any clue but see my answer I have given for THIS[^], and try to give parameters value like that way.
And also show us a full error statement to be further analyzing.
|
|
|
|
|
hi again..i tried to add values like in the link u sent
at that time it given error like "an SqlParameter with parameter name '@firmanin_adi' is not contained by this SqlParameterCollection" in my process layer
vemedya.com
|
|
|
|
|
hi friend it adds the datas now i changed something more after u offered..thanks for help
and one more question; is it too redicilous way to write a method which gets 15 parameters in my process layer and them to call it in my form inside and to assign the parameters here ?
vemedya.com
|
|
|
|
|
That's okey the way you are processing. But Why you have kept a seperate method for InsertData() You should Initialize command there itself. No need for extra garbage. Wrap thing in a function that can be reusable or having something meaning.
You got your problem solved now, I have also found why you were getting error let me tell you if you have found the same or different.
In your event btnEkle_Click you have called h.InsertFirm(firma); directly without setting value for each property, and after finishing a whole operation you are assigning value, I think you're very much newbie with OOPS. try to read some books around will give you better idea on this.
|
|
|
|
|
yeah i am new about it really and try to learn it..i hope it doesnt take much time to improve my skills
thanks for your help again
vemedya.com
|
|
|
|
|
Hi all.
i need to get the ip of a network interface when it is disconnected. i try all the wmi and system.net options afaik, and they give me only when it is a connected network. of course it is a static IP.
thanks for your help.
|
|
|
|
|
Do you know the MAC address of the interface, or can you get it before the interface is disconnected and maintain that information? You might be able to invoke the arp -a command to access the arp cache before it expires to find the lsat known IP address associated with the device. Unfortunately, unless the arp table contains a static entry, the association will be removed within 2 to 10 minutes of going inactive.
Technically speaking, a disconnected device has no IP address, as the address is a network property and it is no longer part of the network. You may configure an interface for a static IP address, but the address is "owned" by the network, and if another device acquires that address while the device is disconnected, it will not operate. While it's disconnected (except for the brief lifetime of the arp cache) it doesn't exist, and no record of it is retained.
Will Rogers never met me.
|
|
|
|
|